Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Arq. bras. cardiol ; 120(5): e20220306, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1439333

RESUMO

Resumo Fundamento O ecocardiograma intracardíaco (EIC) permite visualizar estruturas cardíacas e reconhecer complicações durante a ablação da fibrilação atrial (AFA). Comparado ao ecocardiograma transesofágico (ETE), o EIC é menos sensível para detecção de trombo no apêndice atrial, porém requer mínima sedação e menos operadores, tornando-o atrativo num cenário de recursos restritos. Objetivo Comparar 13 casos de AFA utilizando EIC (grupo AFA-EIC) com 36 casos de AFA utilizando ETE (grupo AFA-ETE). Método Trata-se de corte prospectiva realizada em um único centro. O desfecho principal foi o tempo de procedimento. Desfechos secundários tempo de fluoroscopia, dose de radiação (mGy/cm2), complicações maiores e tempo de internação hospitalar em horas. O perfil clínico foi comparado pelo escore CHA2DS2-VASc. Um valor de p <0,05 foi considerado uma diferença estatisticamente significativa entre os grupos. Resultados A mediana do escore de CHA2DS2-VASc score foi 1 (0-3) no grupo AFA-EIC e 1 (0-4) no grupo AFA-ETE. O tempo total de procedimento foi de 129 ± 27 min grupo AFA-EIC e 189 ± 41 no AFA-ETE (p<0,001); o grupo AFA-EIC recebeu uma dose menor de radiação (mGy/cm2, 51296 ± 24790 vs. 75874 ± 24293; p=0,002), no entanto, o tempo de fluoroscopia em minutos mostrou-se semelhante (27,48 ± 9,79 vs. 26,4 ± 9,32; p=0,671). As medianas do tempo de hospitalização não se mostraram diferentes, 48 (36-72) horas (AFA-EIC) e 48 (48-66) horas (AFA-ETE) (p=0,27). Conclusão Nesta coorte, AFA-EIC foi relacionado a menores tempos de procedimento e menor exposição à radiação, sem aumentar o risco de complicações ou o tempo de internação hospitalar.


Abstract Background Intracardiac echocardiography (ICE) allows visualization of cardiac structures and recognition of complications during atrial fibrillation ablation (AFA). Compared to transesophageal echocardiography (TEE), ICE is less sensitive to detecting thrombus in the atrial appendage but requires minimal sedation and fewer operators, making it attractive in a resource-constrained setting. Objective To compare 13 cases of AFA using ICE (AFA-ICE group) with 36 cases of AFA using TEE (AFA-TEE group). Methods This is a single-center prospective cohort study. The main outcome was procedure time. Secondary outcomes: fluoroscopy time, radiation dose (mGy/cm2), major complications, and length of hospital stay in hours. The clinical profile was compared using the CHA2DS2-VASc score. A p-value <0.05 was considered a statistically significant difference between groups. Results The median CHA2DS2-VASc score was 1 (0-3) in the AFA-ICE group and 1 (0-4) in the AFA-TEE group. The total procedure time was 129 ± 27 min in the AFA-ICE group and 189 ± 41 min in the AFA-TEE group (p<0.001); the AFA-ICE group received a lower dose of radiation (mGy/cm2, 51296 ± 24790 vs. 75874 ± 24293; p=0.002), despite the similar fluoroscopy time (27.48 ± 9. 79 vs. 26.4 ± 9.32; p=0.671). The median length of hospital stay did not differ; 48 (36-72) hours (AFA-ICE) and 48 (48-66) hours (AFA-TEE) (p=0.27). Conclusions In this cohort, AFA-ICE was related to shorter procedure times and less exposure to radiation without increasing the risk of complications or the length of hospital stay.

2.
Rev. urug. cardiol ; 38(1): e405, 2023. ilus, tab
Artigo em Espanhol | LILACS, UY-BNMED, BNUY | ID: biblio-1515549

RESUMO

La ablación de las venas pulmonares se ha convertido en un tratamiento clave para fibrilación auricular (FA). Sin embargo, pueden ocurrir recurrencias. La estrategia disponible para la ablación después de una recurrencia de FA es controvertida, compleja y desafiante, y la información es limitada. Mediante la presentación de una serie de casos se resumen y discuten elementos clave en la comprensión y tratamiento del paciente con FA recurrente sintomática después de un procedimiento inicial de ablación de venas pulmonares que requiere un nuevo procedimiento de ablación. En las últimas décadas se ha obtenido una mejor comprensión de los mecanismos fisiopatológicos implicados en la FA recurrente posterior a ablación de venas pulmonares, lo que permite identificar factores asociados, crear scores predictores e implementar técnicas de optimización o estrategias adicionales para mejorar la durabilidad y la eficacia del aislamiento de venas pulmonares. Debido a que la reconexión de venas pulmonares es un hallazgo típico durante los procedimientos repetidos, ésta debe ser considerada el objetivo principal de una nueva ablación. Las estrategias de ablación adicional (desencadenantes extrapulmonares o sustratos arritmogénicos) son controvertidas y requieren investigaciones futuras.


Pulmonary vein ablation has become a key treatment for atrial fibrillation (AF). However, recurrences can occur. The ideal strategy for ablation after AF recurrence is controversial, complex, and challenging, with limited data available. By presenting a series of cases, we summarize and discuss key elements in the understanding and treatment of patients with symptomatic recurrent AF after an initial pulmonary vein ablation procedure who are subjected to a new ablation procedure. In recent decades, there has been a better understanding of the pathophysiological mechanisms involved in recurrent AF after pulmonary vein ablation, making it possible to identify associated factors, create predictive scores and implement optimization techniques or additional strategies to improve the durability and efficacy of pulmonary veins isolation. Because pulmonary vein reconnection is a typical finding during repeat procedures, it should be considered the primary goal for a repeat ablation procedure. Additional ablation strategies (extrapulmonary triggers or arrhythmogenic substrates) are controversial and require further investigation.


A ablação das veias pulmonares tornou-se um tratamento chave para fibrilação atrial (FA). No entanto, podem ocorrer recorrências. A estratégia ideal para a ablação após uma recorrência da FA é controversa, complexa e desafiadora e existem dados limitados. Através da apresentação de uma série de casos resumimos e discutimos elementos chave no entendimento e tratamento do paciente com FA recorrente sintomática após um procedimento inicial de ablação de veias pulmonares, que são submetidos a um novo procedimento de ablação. Nas últimas décadas obteve-se uma melhor compressão dos mecanismos fisiopatológicos envolvidos na FA recorrente pós-ablação de veias pulmonares, isso permite identificar fatores associados, criar scores preditores, implementar técnicas de otimização ou estratégias adicionais para melhorar a durabilidade e eficácia do isolamento de veias pulmonares. Dado que a reconexão de veias pulmonares é um achado típico durante os procedimentos repetidos deve ser considerado o objetivo principal para uma nova ablação. As estratégias de ablação adicional (desencadeadores extrapulmonares ou substratos arritmogénicos) são controversas e requerem investigação futura.


Assuntos
Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/fisiopatologia , Recidiva , Fibrilação Atrial/fisiopatologia
3.
J. Transcatheter Interv ; 31: eA20230010, 2023. ilus.; vid.
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1516849

RESUMO

A comunicação interatrial do tipo seio venoso superior geralmente acompanha-se de uma conexão venosa anômala de veia ou veias pulmonares superiores ou médias direitas, que drenam diretamente na veia cava superior ou, ainda, na junção cavoatrial. Relatamos o caso de uma paciente do sexo feminino, de 62 anos, com diagnóstico de comunicação interatrial do tipo seio venoso, com sobrecarga das câmaras direitas, para quem foi planejado o procedimento de oclusão percutânea do defeito por meio da realização prévia de tomografia cardiovascular e, sequencialmente, estudo anatômico tridimensional, com o software de acesso público 3D Slicer. Além disso, foi realizada a impressão do modelo em resina para inspeção e simulação de implante de um stent. A paciente foi tratada de maneira percutânea com um stent Chetham-Platinum coberto de 60mm de extensão, com oclusão total do defeito, ausência de shunts residuais e direcionamento do fluxo da veia pulmonar superior direita para o átrio esquerdo por comunicação posterior entre os átrios, condição essencial para a realização desse tipo de procedimento. O planejamento do procedimento de oclusão percutânea da comunicação interatrial do tipo seio venoso passa por avaliação criteriosa dos exames de imagem. A impressão de modelos virtuais ou físicos, derivados da angiotomografia cardíaca, é fundamental para estudo detalhado do defeito e das estruturas anatômicas associadas, minimizando a ocorrência de complicações.


A superior sinus venosus atrial septal defect is usually accompanied by an anomalous venous connection to a right superior or middle pulmonary vein or veins, draining directly into the superior vena cava or even into the cavoatrial junction. This is a case report of a 62-year-old female patient, diagnosed with a sinus venosus atrial septal defect, with overload of the right chambers, for whom a percutaneous occlusion procedure was planned, using a previous cardiovascular tomography and, sequentially, a three-dimensional anatomical study, with the publicly available software 3D Slicer. In addition, a resin model was printed for inspection and simulation of a stent implantation. The patient was treated percutaneously with a 60-mm covered Chetham-Platinum stent, with total occlusion of the defect, absence of residual shunts, and draining flow from the right superior pulmonary vein to the left atrium, through a posterior communication between the atria, a sine qua non prerequisite to perform this type of procedure. Planning of the percutaneous occlusion procedure of the sinus venosus atrial septal defect involves careful evaluation of imaging tests. The printing of virtual or physical models, derived from computed tomography angiography of the heart, is essential for a detailed study of the defect and associated anatomical structures, minimizing the occurrence of complications.

4.
Arq. bras. cardiol ; 117(1): 100-105, July. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1285226

RESUMO

Resumo Fundamento Na fibrilação atrial paroxística (FAP), o isolamento das veias pulmonares com criobalão (IVP-CB) tem eficácia semelhante à da ablação por radiofrequência (IVP-RF). Em procedimentos de reablação após IVP-RF, a reconexão das VPs é alta, ao passo que em pacientes com reablação após IVP-CB, as informações são escassas. Objetivo Determinar os locais de reconexão das VPs em pacientes que foram submetidos à reablação após IVP-CB inicial. Métodos Pacientes que foram submetidos a um procedimento de reablação de fibrilação atrial, após um IVP-CB inicial para FAP foram incluídos. O mapeamento eletroanatômico do AE foi utilizado. Um local de reconexão foi definido com a presença de uma voltagem de 0,3mV ou maior nas VPs e condução unidirecional ou bidirecional nas VPs durante o ritmo sinusal. Os locais de reconexão foram identificados por meio de corte paraesternal longitudinal e posteriormente ablacionados com radiofrequência. Resultados Dos 165 pacientes submetidos ao IVP inicial, 27 necessitaram reablações, dos quais 18 (66,6%) eram do sexo masculino, com média de idade de 55+12,3 anos. O tempo de recorrência foi de 8,9+6,4 meses. A reconexão das VPs foi encontrada em 21 (77,8%) pacientes. Houve um total de 132 lacunas de condução, seis por paciente, 3,6 por VP. Um número significativo de lacunas ocorreu na região ântero-superior da VP superior esquerda (VPSE) e nas regiões septal e inferior da VP superior direita (VPSD). Conclusões As VPs superiores apresentaram os locais de maior reconexão, principalmente na região anterior da VPSE e na região septal da VPSD. A razão por trás disso pode ser devido à maior espessura da parede atrial e à dificuldade em alcançar o contato de criobalão adequado.


Abstract Background In paroxysmal atrial fibrillation (PAF), pulmonary vein isolation using cryoballoon (CB-PVI) has similar efficacy as radiofrequency ablation (RF-PVI) has. In redo ablation procedures following RF-PVI, PV reconnection is high, whereas in patients with redo following CB-PVI, information is scarce. Objective To determine the sites of PV reconnection in patients who underwent redo ablation after initial CB-PVI. Methods Patients who underwent an AF redo procedure, following an initial CB-PVI for PAF were included. LA electroanatomic mapping was used. A reconnection site was defined as the presence of a voltage of 0.3mV or greater in the PV and unidirectional or bidirectional conduction in the PV during sinus rhythm. Reconnections sites were identified using a clock-face view description and were ablated with radiofrequency afterwards. Results Out of the 165 patients who underwent initial PVI, 27 required redo ablations, of which 18 (66.6%) were males, with a mean age of 55+12.3 years. The time of recurrence was 8.9+6.4 months. PV reconnection was found in 21 (77.8%) patients. There was a total of 132 conduction gaps, six per patient, 3.6 per PV. A significant number of gaps were in the anterosuperior region of the left superior PV (LSPV), and in the septal and inferior regions of the right superior PV (RSPV). Conclusions The upper PVs had the most reconnection sites, mostly at the anterior region of the LSPV and the septal region of the RSPV. The reason behind this may be due to greater atrial wall thickness, and difficulty in achieving adequate cryoballoon contact.


Assuntos
Humanos , Masculino , Adulto , Idoso , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Recidiva , Resultado do Tratamento , Pessoa de Meia-Idade
7.
Arq. bras. cardiol ; 115(3): 528-535, out. 2020. tab, graf
Artigo em Português | LILACS, Sec. Est. Saúde SP | ID: biblio-1131326

RESUMO

Resumo Fundamento O isolamento elétrico das veias pulmonares é reconhecidamente base fundamental para o tratamento não farmacológico da fibrilação atrial (FA) e, portanto, tem sido recomendado como passo inicial na ablação de FA em todas as diretrizes. A técnica com balão de crioenergia, embora amplamente utilizada na América do Norte e Europa, ainda se encontra em fase inicial em muitos países em desenvolvimento, como o Brasil. Objetivo Avaliar o sucesso e a segurança da técnica de crioablação em nosso serviço, em pacientes com FA paroxística e persistente. Métodos Cento e oito pacientes consecutivos com FA sintomática e refratária ao tratamento farmacológico foram submetidos à crioablação para isolamento das veias pulmonares. Os pacientes foram separados em dois grupos, de acordo com a classificação convencional da FA paroxística (duração de até sete dias) e persistente (FA por mais de sete dias). Dados de recorrência e segurança do procedimento foram analisados respectivamente como desfechos primário e secundário. O nível de significância adotado foi de 5%. Resultados Cento e oito pacientes, com idade média de 58±13 anos, 84 do sexo masculino (77,8%), foram submetidos ao procedimento de crioablação de FA. Sessenta e cinco pacientes apresentavam FA paroxística (60,2%) e 43, FA persistente (39,2%). O tempo médio do procedimento foi de 96,5±29,3 minutos e o tempo médio de fluoroscopia foi de 29,6±11,1 minutos. Foram observadas cinco (4,6%) complicações, nenhuma fatal. Considerando a evolução após os 3 meses iniciais, foram observadas 21 recorrências (19,4%) em período de um ano de seguimento. As taxas de sobrevivência livre de recorrência nos grupos paroxístico e persistente foram de 89,2% e 67,4%, respectivamente. Conclusão A crioablação para isolamento elétrico das veias pulmonares é um método seguro e eficaz para tratamento da FA. Nossos resultados estão consoantes com demais estudos, que sugerem que a tecnologia pode ser utilizada como abordagem inicial, mesmo nos casos de FA persistente. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Electrical isolation of the pulmonary veins is recognized as the cornerstone of non-pharmacological treatment of Atrial Fibrillation (AF), and therefore, has been recommended as the first step in AF ablation according to all guidelines. Even though the cryoballoon technology is widely used in North America and Europe, this experience is still incipient in many developing countries such as Brazil. Objective To evaluate initial results regarding success and safety of the new technology in patients with persistent and paroxysmal AF. Methods One hundred and eight consecutive patients with symptomatic AF refractory to pharmacological treatment were submitted to cryoablation for isolation of the pulmonary veins. Patients were separated into two groups according to AF classification: persistent (AF for over one week); or paroxysmal (shorter episodes). Recurrence and procedural safety data were analyzed respectively as primary and secondary outcomes. The level of significance was 5%. Results One hundred and eight patients, with mean age 58±13 years, 84 males (77.8%), underwent cryoablation. Sixty-five patients had paroxysmal AF (60.2%) and 43 had persistent AF (39.2%). The mean time of the procedure was 96.5±29.3 minutes and the mean fluoroscopy time was 29.6±11.1 minutes. Five (4.6%) complications were observed, none fatal. Considering a blanking period of 3 months, 21 recurrences (19.4%) were observed in a one-year follow-up period. The recurrence-free survival rates of AF in the paroxysmal and persistent groups were 89.2% and 67.4%, respectively. Conclusion Cryoablation for electrical isolation of the pulmonary veins is a safe and effective method for the treatment of AF. Our results are consistent with other studies suggesting that this technology can be used as an initial technique even in cases of persistent AF.


Assuntos
Humanos , Masculino , Idoso , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Recidiva , Brasil , Resultado do Tratamento , Pessoa de Meia-Idade
9.
Rev. urug. cardiol ; 35(1): 231-248, 2020. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1156860

RESUMO

Resumen: La ablación de la fibrilación auricular mediante el aislamiento de las venas pulmonares, es una estrategia ampliamente utilizada en la actualidad. La recurrencia posablación es un problema frecuente. Se han investigado varios predictores de recurrencia con el fin de optimizar la elección del paciente que más se beneficia del procedimiento. Actualmente la evidencia es controvertida, siendo necesarios más estudios al respecto.


Summary: The ablation of atrial fibrillation based on pulmonary veins isolation, is a widely used strategy nowadays. Post ablation recurrence is a frequent problem. Several recurrence predictors have been researched, with the purpose of choosing the patient that would benefit the most from this procedure. Current evidence is controversial and more research is needed.

10.
Arq. bras. cardiol ; 111(6): 824-830, Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973806

RESUMO

Abstract Background: Pulmonary veins (PV) are often the trigger to atrial fibrillation (AF). Occasionally, left PVs converge on a common trunk (LCT) providing a simpler structure for catheter ablation. Objective: To compare the clinical characteristics and outcomes of ablation in paroxysmal atrial fibrillation (PAF) of patients with or without LCT. Methods: Case-control study of patients undergoing first-ever catheter ablation procedure for drug refractory PAF. The information was taken from patients' records by means of a digital collection instrument, and indexed to an online database (Syscardio(r)). Clinical characteristics and procedures were compared between patients with or without LCT (LCT x n-LCT), adopting a level of statistical significance of 5%. The primary endpoint associated with efficacy was lack of atrial arrhythmia over the follow-up time. Results: One hundred and seventy two patients with PAF were included in the study, 30 (17%) LCT and 142 (83%) n-LCT. The clinical characteristics, comorbidities, symptoms scale and risk scores did not differ between the groups. There was AF recurrence in 27% of PAF patients in the n-LCT group and only 10% of patients in the LCT group (OR: 3.4 p: 0.04) after a follow-up of 34 ± 17 months and 26 ± 15 months respectively. Conclusion: Patients with a LCT have a significantly lower recurrence rate when compared to patients without this structure. It is mandatory to report the results of AF catheter ablation as a PV anatomical variation function.


Resumo Fundamento: As veias pulmonares (VP) são frequentemente o local de origem da fibrilação atrial (FA). Ocasionalmente, as VPs esquerdas confluem em um tronco comum (TrCE) proporcionando uma estrutura mais simples para ablação por cateter. Objetivos: Tem-se como objetivo comparar as características clínicas e os resultados da ablação em pacientes portadores de FA paroxística (FAP) com ou sem TrCE. Metódos: Estudo do tipo caso-controle de pacientes submetidos ao primeiro procedimento de ablação por cateter para FAP refratária a drogas antiarrítmicas. As informações foram retiradas dos prontuários dos pacientes por meio de instrumento digital de coleta e indexadas a uma base de dados online (Syscardio(r)). As características clínicas e procedimentos foram comparados entre pacientes com e sem TrCE (TrCE x n-TrCE), sendo adotado nível de significância estatística de 5%. O desfecho primário associado à eficácia foi ausência de arritmia atrial ao longo do seguimento com único procedimento. Resultados: Cento e setenta e dois pacientes foram incluídos no estudo, 30 (17%) TrCE e 142 (83%) n-TrCE. As características clínicas, comorbidades, severidade de sintomas e escores de risco não apresentaram diferença estatística entre os grupos. Houve recorrência da FA em 27% dos pacientes do grupo não-TrCE e em apenas 10% dos pacientes do grupo TrCE (OR: 3,4 p: 0.04) após um seguimento de 34±17 e 26±15 meses respectivamente. Conclusão: Pacientes com TrCE apresentam significativamente menor taxa de recorrência quando comparados a pacientes sem esta estrutura. É imprescindível relatar os resultados da ablação por cateter de FA na vigência de variações anatômicas das VPs.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/anatomia & histologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Recidiva , Tomografia Computadorizada por Raios X , Estudos de Casos e Controles , Seguimentos , Resultado do Tratamento , Estimativa de Kaplan-Meier
12.
Arq. bras. cardiol ; 110(5): 440-448, May 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-950162

RESUMO

Abstract Background: The influence of pulmonary vein (PV) anatomy on cryo kinetics during cryoballoon (CB) ablation is unclear. Objective: To investigate the relationship between PV anatomy and cryo kinetics during CB ablation for atrial fibrillation (AF). Methods: Sixty consecutive patients were enrolled. PV anatomy, including ostial diameters (long, short and corrected), ratio between short and long diameters, ostium shape (round, oval, triangular, and narrow), and drainage pattern (typical, with common trunk, common antrum, ostial branch and supernumerary PV) were evaluated on multi-detector computed tomography (MDCT) images pre-procedure. Cryo kinetics parameters [balloon freeze time from 0 to -30ºC (BFT), balloon nadir temperature (BNT) and balloon warming time from -30 to +15ºC (BWT)] were recorded during procedure. All p values are two-sided, with values of p < 0.05 considered to be statistically significant. Results: 606 times of freezing cycle were accomplished. Moderate negative correlation was documented between BNT and corrected PV diameter (r = -0.51, p < 0.001) when using 23-mm CBs, and mild negative correlation (r = - 0.32, p = 0.001) was found when using 28-mm CBs. Multivariate logistic regression analysis revealed that PV corrected ostial diameter (OR, 1.4; p = 0.004) predicted a BNT < -51ºC when using 23-mm CBs, while PV ostium oval shape (OR, 0.3; p = 0.033) and PV locations (left inferior PV: OR, 0.04; p = 0.005; right superior PV: OR, 4.3; p = 0.025) predicted BNT < -51ºC when using 28-mm CBs. Conclusions: MDCT can provide PV anatomy accurate evaluation prior CB ablation. PV anatomy is associated with cryo kinetics during ablation.


Resumo Fundamentos: A influência da anatomia da veia pulmonar (VP) na criocinética durante a ablação por criobalão (CB) não está clara. Objetivo: Investigar a relação entre a anatomia da VP e a criocinética durante a ablação com CB para fibrilação atrial (FA). Métodos: sessenta pacientes consecutivos foram matriculados. Foram avaliados em imagens de tomografia computadorizada multidetectora (TCMD) pré-procedimento a anatomia da VP, incluindo diâmetros dos óstios (longo, curto e corrigido), relação entre diâmetros curtos e longos, forma do óstio (redondo, oval, triangular e estreito) e padrão de drenagem (típico, com tronco comum, antro comum, ramo ostial e VP supranumerária). Os parâmetros criocinéticos [tempo de congelamento de balão de 0 a -30ºC (TCB), temperatura do nadir do balão (TNB) e tempo de aquecimento do balão de -30 a + 15ºC (TAB)] foram registrados durante o procedimento. Todos os valores de p são bicaudais, com valores de p < 0,05 considerados estatisticamente significativos. Resultados: o ciclo de congelamento foi realizado 606 vezes. Correlação negativa moderada foi documentada entre o TNB e o diâmetro VP corrigido (r = - 0,51, p < 0,001) ao usar CBs de 23 mm e correlação negativa leve (r = - 0,32, p = 0,001) foi encontrada ao usar 28- mm CBs. A análise de regressão logística multivariada revelou que o diâmetro corrigido do óstio da VP (OR, 1,4; p = 0,004) previu um TNB < -51ºC ao usar CB de 23 mm, enquanto a forma oval do óstio VP (OR, 0,3; p = 0,033) e as localizações da VP (VP inferior: OR, 0,04; p = 0,005; VP superior direito: OR, 4,3; p = 0,025) previram TNB < -51ºC ao usar CBs de 28 mm. Conclusões: A TCMD pode fornecer uma avaliação precisa da anatomia da VP antes da ablação por CB. A anatomia da VP está associada à criocinética durante a ablação.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/anatomia & histologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Cinética , Tomografia Computadorizada por Raios X , Estudos Prospectivos , Resultado do Tratamento , Imageamento Tridimensional
13.
Rev Port Cardiol ; 36(11): 869.e1-869.e4, 2017 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29128137

RESUMO

Total anomalous pulmonary venous connection (TAPVC) with direct connection of the pulmonary veins to the morphologically right atrium is exceedingly rare other than in the setting of isomerism of the right atrial appendages. We present an interesting case of TAPVC in a patient with situs solitus that connected to the right atrium via a broad-mouthed common chamber.


Assuntos
Anormalidades Múltiplas , Átrios do Coração/anormalidades , Síndrome de Cimitarra/classificação , Anormalidades Múltiplas/diagnóstico por imagem , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Lactente , Masculino , Síndrome de Cimitarra/diagnóstico por imagem
14.
Rev Port Cardiol ; 35(12): 697.e1-697.e6, 2016 Dec.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27865671

RESUMO

Anomalous pulmonary venous connection is an uncommon congenital anomaly in which all (total form) or some (partial form) pulmonary veins drain into a systemic vein or into the right atrium rather than into the left atrium. The authors present one case of total anomalous pulmonary venous connection and two cases of partial anomalous pulmonary venous connection, one of supracardiac drainage into the brachiocephalic vein, and the other of infracardiac anomalous venous drainage (scimitar syndrome). Through the presentation of these cases, this article aims to review the main pulmonary venous developmental defects, highlighting the role of imaging techniques in the assessment of these anomalies.


Assuntos
Veias Pulmonares/anormalidades , Síndrome de Cimitarra/diagnóstico por imagem , Adolescente , Criança , Feminino , Átrios do Coração , Humanos , Achados Incidentais , Lactente , Imageamento por Ressonância Magnética , Masculino , Veias Pulmonares/diagnóstico por imagem , Síndrome de Cimitarra/terapia , Tomografia Computadorizada por Raios X
15.
Rev Port Cardiol ; 35(7-8): 443.e1-4, 2016.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27395560

RESUMO

The authors report a case of multiple pulmonary varices, a rare disease characterized by aneurysmatic venous dilatations, which can be present at any age and without gender predominance, occurring in isolation or associated with obstruction of the pulmonary veins. This condition usually manifests as a lung mass with variable clinical consequences.


Assuntos
Veias Pulmonares/diagnóstico por imagem , Varizes/diagnóstico por imagem , Adulto , Feminino , Humanos , Pulmão/irrigação sanguínea , Circulação Pulmonar , Varizes/terapia
17.
ABC., imagem cardiovasc ; 29(1): 25-27, jan.-mar.2016. ilus
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: lil-777620

RESUMO

A fibrilação atrial (FA) é a arritmia cardíaca sustentadamais frequente na prática clínica. Dados epidemiológicosdemonstram que a FA está associada a morbidadee a mortalidade expressivas, acarretando custosmédico-hospitalares elevados.1 O desalento geradopelo impacto modesto dos agentes antiarrítmicos nahistória natural da FA motivou o desenvolvimento demétodos não farmacológicos, visando o tratamentocurativo dessa arritmia. Nesse contexto, na últimadécada, a ablação por cateter com técnicas percutâneasevoluiu consideravelmente, consolidando-se comoopção terapêutica em pacientes selecionados com FA.2Métodos de imagem, tais como ecocardiografia intracardíacae mapeamento eletroanatômico, têm sido cada vez maisincorporados, com a finalidade de aumentar a eficiência ea segurança do método. A eficácia da ablação vem sendodiscutida nos últimos tempos buscando-se evidenciarfatores que contribuem para as taxas de recorrência daFA. A falha do procedimento é muitas vezes atribuídaà retomada da condução entre as veias pulmonares e oátrio esquerdo em razão da ablação incompleta dos focosectópicos.3...


Assuntos
Humanos , Masculino , Adulto , Ablação por Cateter/métodos , Espectroscopia de Ressonância Magnética/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Veias Pulmonares , Arritmias Cardíacas , Ecocardiografia/métodos , Resultado do Tratamento , Átrios do Coração
19.
Rev Port Cardiol ; 33(6): 383.e1-5, 2014 Jun.
Artigo em Português | MEDLINE | ID: mdl-25001162

RESUMO

Anomalous pulmonary venous return (APVR) is a rare cardiac anomaly defined as one or more pulmonary veins draining into a structure other than the left atrium, with venous return directly or indirectly to the right atrium. The most common form is partial APVR, in which one to three pulmonary veins drain into systemic veins or into the right atrium. We report the case of a woman diagnosed with partial APVR by magnetic resonance imaging during pregnancy.


Assuntos
Técnicas de Imagem Cardíaca , Imageamento por Ressonância Magnética , Complicações Cardiovasculares na Gravidez/diagnóstico , Síndrome de Cimitarra/diagnóstico , Feminino , Humanos , Gravidez
20.
Radiol. bras ; 46(6): 376-378, Nov-Dec/2013. graf
Artigo em Inglês | LILACS | ID: lil-699245

RESUMO

Unilateral pulmonary vein atresia is a rare congenital condition. In addition to cardiac malformations or pulmonary hypertension, patients may present with recurrent pulmonary infections or hemoptysis in childhood or adolescence. The authors report a case where the typical findings of such condition were observed at computed tomography in an adult patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...